Determination method optimization for residual solvent in flaxseed oil
CSTR:
Author:
Affiliation:

1Ulanqab Inspection and Testing Center, Ulanqab, Inner Mongolia 012000, China;2Ulanqab Agricultural and Livestock Product Quality and Safety Center, Ulanqab, Inner Mongolia 012000, China

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective To optimize the determination method for residual solvent in flaxseed oil.Methods Test flaxseed oil samples are separated using a methyl polysiloxane capillary column containing 6% cyanopropyl-phenyl by headspace gas chromatograph (HS-GC).Results The linear correlation coefficient of solvent No. 6 is 0.999 9, and the average spiked recovery rate is 91.0% to 102.3%. The original interference peak of flaxseed oil does not appear within the time range of the target peak of solvent No. 6. Additionally, other common vegetable oils do not have interference peaks with large peak areas.Conclusion HS-GC can be used to determine the residual solvent in common vegetable oils.