Numerical simulation and optimization of gas-liquid two-phase flow in a large-scale bubble column bioreactor
CSTR:
Author:
Affiliation:

1.Angel Yeast Co., Ltd., Yichang, Hubei 443000, China;2.National Key Laboratory of Agricultural Microbiology, Yichang, Hubei 443000, China;3.The Hubei Provincial Key Laboratory of Yeast Function, Yichang, Hubei 443000, China;4.State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai 200234, China

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective To conduct flow field simulation analysis on an 80-ton bubble column bioreactor for equipment improvement and fermentation efficiency enhancement.Methods Computational fluid dynamics is resorted to numerical simulation of gas-liquid two-phase flow in a bubble column bioreactor. Euler-Euler method and k-ε model are used to simulate the turbulence of gas-liquid two-phase flow. The population balance model (PBM) is coupled to predict bubble size. The flow pattern, liquid velocity, energy dissipation rate, gas holdup, and bubble size distribution inside the reactor are simulated. Based on the permeation model, the calculation is performed on the volumetric oxygen transfer coefficient (kLa) inside the reactor, and an analysis is conducted on the influence of different reflux angles and diameters of the reflux pipe on the reactor’s oxygen supply capacity.Results The reflux pipe significantly impacts the reactor’s flow field, and positively impacts the liquid velocity, energy dissipation rate, and bubble size. The volumetric oxygen transfer coefficient of the reactor reaches 1 093 h-1. There is an interactive effect between the reflux angle and the diameter of the reflux pipe, with the optimal combination as a diameter of 150 mm and an angle of 45°. Under these conditions, the volumetric oxygen transfer coefficient reaches 1 428 h-1.Conclusion The reflux pipe makes the bubble column reactor comparable to the stirred reactor of the same scale in terms of oxygen supply capacity, playing a crucial role.

    Reference
    Related
    Cited by
Get Citation

王龙,孙雅芳,覃先武,等.大型鼓泡式生物反应器气液两相流的数值模拟及优化[J].食品与机械英文版,2025,41(10):59-66.

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:January 26,2024
  • Revised:April 15,2025
  • Adopted:
  • Online: November 20,2025
  • Published:
Article QR Code