Determination of 7 synthetic colorants in freshly prepared beverages by high performance liquid chromatography dual wavelength method with automatic solid phase extraction
CSTR:
Author:
Affiliation:

(1. The Affiliated Wuxi Center for Disease Control and Prevention of Nanjing Medical University, Wuxi Center for Disease Control and Prevention,Wuxi, Jiangsu 214023, China; 2. Karamay City Center for Disease Control and Prevention, Karamay, Xinjiang 834000, China; 3. Wuxi Food Safety Inspection and Test Center, Wuxi, Jiangsu 214142, China; 4. Technology Innovation Center of Special Food for State Market Regulation, Wuxi, Jiangsu 214142, China)

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective: A method for the determination of 7 synthetic colorants in freshly prepared beverages by high performance liquid chromatography dual (HPLC) wavelength method with automatic solid phase extraction was established. Methods: Extraction conditions: The sample was extracted 2 times with pure water, and then the supernatant combined after centrifugation. The pH of the supernatant was adjusted to 3~4. After activation by an automatic solid-phase extraction device, loading, rinsing, and elution of the sample were carried out on the Poly-sery synthetic colorant solid-phase extraction column. The eluent was concentrated to 200 μL by nitrogen blowing, and then fixed to 1.0 mL with 50% mobile phase A+50% mobile phase B. Instrument conditions: The column was C18 column. The mobile phase was 20 mmol/L ammonium acetate-methanol, gradient elution. The flow rate was 1.0 mL/min. The injection volume was 10 μL. The detection wavelength were 254 nm and 628 nm. Results: The correlation coefficient of each substance in the range of 0.5~50 μg/mL was greater than 0.999 9, the detection limit of the method was 0.023~0.179 mg/kg, the quantitative limit was 0.078~0.598 mg/kg, the standard recovery was 92.4%~96.8%, and the relative standard deviation (RSD) was 1.2%~4.2%. Conclusion: This method has low consumption of toxic reagents, simple operation steps, high degree of automation, good recovery and repeatability, and it is suitable for the determination of large quantities of samples.

    Reference
    Related
    Cited by
Get Citation

姚誉阳,徐 曼,潘春燕,等.全自动固相萃取—高效液相色谱法测定现制饮料中7种合成着色剂[J].食品与机械英文版,2024,40(3):82-88,94.

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:June 25,2023
  • Revised:
  • Adopted:
  • Online: April 30,2024
  • Published: