Research on performance of NH3/CO2 cascade refrigeration system with variable rotation speed
CSTR:
Author:
Affiliation:

(1. College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China; 2. Shanghai Professional Technology Service Platform on Cold Chain Equipment Performance and Energy Saving Evaluation, Shanghai 201306, China; 3. Shanghai Engineering Research Center of Aquatic Product Processing & Preservation, Shanghai 201306, China; 4. National Experimental Teaching Demonstration Center for Food Science and Engineering 〔Shanghai Ocean University〕, Shanghai 201306, China)

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective: This study aimed to research the influence of different rotation speed of high-temperature compressor on the performance of NH3/CO2 cascade refrigeration system under various seasons and evaporation temperature of 25 ℃. Methods: The NH3/CO2 cascade refrigeration system model was established and its reliability was verified in this paper. The relationship between the rotation speed of high-temperature compressor and the evaporation temperature, the discharge temperature, the intermediate temperature, high-temperature compressor power, cooling capacity, Coefficient of Performance (COP) of cascade refrigeration system was calculated and analyzed. Results: The relative error of the simulation model for predicting the heat transfer was less than 14.1%. The cooling capacity of the system in spring, summer, autumn and winter respectively increases by 31.7%, 41.7%, 33.9% and 25.2% as the rotation speed of the high-temperature compressor increased from 2 300 r/min to 3 300 r/min, and the cooling capacity was the highest in winter in the low-speed range. In addition, high temperature compressor power showed a two-stage upward trend, increased by 40%~45%. Conclusion: There was a maximum COP and corresponding optimal high- temperature compressor speed. Based on the adaptability of the system to different seasons, a scheme of variable rotation speed NH3/CO2 cascade refrigeration system is proposed. Compared with the system with constant speed, the power consumption could be reduced by 19.9% per year.

    Reference
    Related
    Cited by
Get Citation

叶梦莹,顾众,谢晶.不同季节工况下变转速NH3/CO2复叠制冷系统性能研究[J].食品与机械英文版,2021,(9):104-109.

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:March 16,2021
  • Revised:
  • Adopted:
  • Online: February 15,2023
  • Published:
Article QR Code