Fluorescence aptasensor detection of chloramphenicol based on MnO2 nanosheet and Exo-I
CSTR:
Author:
Affiliation:

(1. State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, China; 2. School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, China)

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In order to develop rapid detection method for chloramphenicol in food, in this study, a novel chloramphenicol aptasensor was constructed based on fluorescence quenching ability of MnO2 nanosheet and fluorescence amplification ability of Exo-I digestion. Results showed that under optimal fluorescence detection conditions of 50 nmol/L concentration of aptamer, 0.05 mg/mL concentration of MnO2 nanosheet, 0.4 U/μL concentration of Exo-I and Exo-I digestion time of 50 minutes, and the fluorescence intensity had a good linear relationship with the concentration of chloramphenicol (R2=0.995). The linear range of detection was 0.1~80.0 nmol/L with the detection limit of 0.08 nmol/L. The constructed detection approach had the advantages of simple operation and high sensitivity, and could realize accurate detection of chloramphenicol in food samples.

    Reference
    Related
    Cited by
Get Citation

马鹏飞,齐硕,吕艳,等.基于二氧化锰纳米片和核酸外切酶I构建荧光适配体传感器检测氯霉素[J].食品与机械英文版,2021,37(4):53-57.

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 13,2020
  • Revised:
  • Adopted:
  • Online: February 15,2023
  • Published:
Article QR Code