Determination of retinol palmitate and retinol acetate in formulas for special medical purposes intended for infants by HPLC
CSTR:
Author:
Affiliation:

(1. Hunan Provincial Food Quality Supervision and Inspection Institute, Changsha, Hunan 410011, China; 2. Changsha Environmental Protection Voctional College, Changsha, Hunan 410004, China)

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Retinol palmitate and retinol acetate in formulas for special medical purposes intended for infants was determined using NP-HPLC. The HPLC system consisted of NH2 column (150 mm×4.6 mm, 5.0 μm), mobile phase of n-hexane-25.0% tert-butyl methyl ether n-hexane solution (955), flow rate of 1.0 mL/min, injection volume of 50 μL, column temperature of 30 ℃, UV detector detection wavelength of 325 nm. Results showed that retention time of retinol palmitate and retinol acetate were 3.5 min and 6.0 min, respecitively the linearity was good in the range of 0.05~10.0 μg/mL with a correlation coefficient of 0.999 9, the detection limits were 2.0 and 2.5 μg/100 g respectively. The content of retinol palmitate and retinol acetate in formulas for special medical purposes intended for infants were 0~817.0 and 0~8 683.0 μg/100 g, the precision were 0.9%~9.4% and 3.3%~6.3% respecitively. The recoveries of spiked samples at three levels were 81.0%~90.0%. The developed method presented the benefits of simplicity, rapidity, good separation, high accuracy, high precision.

    Reference
    Related
    Cited by
Get Citation

李涛,周艳华,孙桂芳,等. HPLC法测定特殊医学用途婴配食品中视黄醇棕榈酸酯和视黄醇醋酸酯[J].食品与机械英文版,2018,34(5):91-94.

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 18,2017
  • Revised:
  • Adopted:
  • Online: March 17,2023
  • Published:
Article QR Code