Abstract:According to the low flavoring accuracy in the traditional frequency conversion feeding pump drive system,the the feed pump drive system was improved, the servo motor system was used to drive the liquid feeding, and the control program is optimized. After the modification of the system, the cumulative added essence increased from 0.09% to 0.15%, to ensure the uniformity of spiced charging, improve the product quality, reduce the production cost.