Determination of Cd in Shrimps by microwave digestion and inductively coupled plasma mass spectrometry
CSTR:
Author:
Affiliation:

(University of Shanghai for Science and Technology, Shanghai 200093, China)

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The orthogonal array design methods were applied to analyze the influence of H2O2 volume/HNO3 volume/microwave digestion time three factors and their interaction on the extraction of Cd,select an optimized progress to extract Cd from shrimps. The experimental results showed that when H2O2 volume was 1.0 mL, HNO3 volume is 5.0 mL, microwave digestion time was 13 minutes and 46 seconds, under these conditions,the contents of Cd reached 0.497 mg/kg. Determination of GBW10050 (big shrimps) showed that contents of Cd have the same results with standards values. Method limits of detection were obtained within the range of 0.01 μg /kg,the precision for this method was better than 5%. It allowed simple, rapid, sensitive and accurate determination of Cd in shrimps.

    Reference
    Related
    Cited by
Get Citation

李倩云,周国燕,曹蕾.微波消解—电感耦合等离子体质谱法检测虾中镉含量的工艺优化[J].食品与机械英文版,2016,32(5):63-66.