Using GC—MS and ELISA kits for comparative analysis of plasticizers in red wine
CSTR:
Author:
Affiliation:

(1. College of Life Sciences, South China Agricultural University, Guangzhou, Guangdong 510642, China; 2. College of Food Science, South China Agricultural University, Guangzhou, Guangdong 510642, China)

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    There were two methods to detect the plasticizers of red wine. The first one was a traditional method(GC-MS) and another one was a new method-ELISA kit. An improved pre-processing of GC-MS and the comparative analysis of the two methods was used to find a novel detection method. The results: there was a little difference for the rate of plasticizer extraction with different pre-treatment. And DIBP, DBP, DEHP were detected. The GC-MS method demonstrated high precision and recovery. The GC-MS method was a excellent method to detect the plasticizers of red wine. The detection results of ELISA kit were 3.4 to 5.5 times larger than the GC-MS method. It was enough for ELISA kit as a rapid detection method of the plasticizers of red wine.

    Reference
    Related
    Cited by
Get Citation

曹必溥,曹庸,苗建银,等. ELISA试剂盒法与GC—MS法检测红酒中塑化剂的比较研究[J].食品与机械英文版,2015,31(1):82-85,115.