A fluorescence ELISA based on dsDNA-CuNCs for the detection of E. coli O157:H7 in milk
Author:
Affiliation:

(1. College of Food Science, Nanchang University, Nanchang, Jiangxi 330047, China; 2. College of Life Science, Jiangxi Normal University, Nanchang, Jiangxi 330022, China; 3. Jiangxi Provincial Center for Disease Control and Prevention, Nanchang, Jiangxi 330029, China; 4. Jiangxi Provincial Key Laboratory of Diagnosing and Tracing of Foodborne Disease, Nanchang, Jiangxi 330029, China; 5. School of Food Science and Bioengineering, Changsha University of Science & Technology, Changsha, Hunan 410114, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:建立了一种灵敏检测牛奶中大肠杆菌O157:H7的新型荧光酶联免疫吸附方法。方法:以碱性磷酸酶水解焦磷酸盐-Cu2+配位复合物,释放出Cu2+形成铜纳米簇作为信号报告探针,通过对关键因素Cu2+浓度、焦磷酸盐浓度、DNA模板的浓度和长度进行优化。结果:在最优条件下,大肠杆菌O157:H7的菌数为5×104~1×108 CFU/mL时,与荧光信号值有较好的线性关系(R2=0.980 8),最低检出限为2.4×104 CFU/mL。结论:该方法成功地应用于低脂牛奶和脱脂牛奶样本中大肠杆菌O157:H7的测定,平均回收率为92.2%~108.5%,相对标准偏差为4.9%~10.4%。

    Abstract:

    Objective: This study aimed to developed a novel fluorescent enzyme-linked immunosorbent assay method for the sensitive detection of E. coli O157:H7 in milk samples. Methods: The pyrophosphate-Cu2+ coordination complex was hydrolyzed by alkaline phosphatase, and Cu2+ was released from copper nanoclusters as signal reporting probes. Key factors such as Cu2+ concentration, pyrophosphate concentration, and DNA template concentration and length were optimized. Results: Under the control of the optimized conditions, the method exhibited a good linear relationship (R2=0.980 8) with the target E. coli O157:H7 in the range of 5×104~1×108 CFU/mL. The limit of detection was 2.4×104 CFU/mL. Conclusion: The method was successfully applied to the determination of E. coli O157:H7 in samples of low-fat milk and skim milk. The average recovery was 92.2% ~ 108.5% with relative standard deviation 4.9% ~ 10.4%.

    参考文献
    相似文献
    引证文献
引用本文

曹文凯,山 珊,刘道峰,等.基于dsDNA-CuNCs的荧光ELISA检测牛奶中的E. coli O157:H7[J].食品与机械,2023,39(9):38-43,94.
CAO Wenkai, SHAN Shan, LIU Daofeng, et al. A fluorescence ELISA based on dsDNA-CuNCs for the detection of E. coli O157:H7 in milk[J]. Food & Machinery,2023,39(9):38-43,94.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-10-30
  • 出版日期:
文章二维码
×
《食品与机械》
友情提示
友情提示 一、 近日有不少作者反应我刊官网无法打开,是因为我刊网站正在升级,旧网站仍在百度搜索排名前列。请认准《食品与机械》唯一官方网址:http://www.ifoodmm.com/spyjx/home 唯一官方邮箱:foodmm@ifoodmm.com; 联系电话:0731-85258200,希望广大读者和作者仔细甄别。