    摘要:

    目的:为卷烟厂车间提供一种简单、快速测定卷烟纸中钾含量的方法。方法:采用离子选择性电极法,比较卷烟纸样品的预处理方法,比较钾离子选择电极在不同缓冲溶液中的电位响应行为。结果:钾离子选择电极在醋酸锂缓冲溶液(0.1 mol/L,pH 7.0)中具有优异的响应性能,对K+的线性响应范围为1.0×10-5~1.0×10-2mol/L,线性响应斜率为55.79 mV/dec (25 ℃),检测下限可达到2.14×10-6mol/L。钾离子选择性电极对卷烟纸样品的日内测试平均相对标准偏差为0.55%,日间测试相对标准偏差为2.8%,均<5%。电极方法与离子色谱法的测试结果一致,平均相对偏差为4.1%(n=10),回收率为95.0%~101.9%,在连续1周的测试过程中展示出良好的时效性。结论:卷烟纸样品预处理方法中,采用1%稀醋酸超声萃取30 min提取钾离子快速简单,环保易行,离子选择性电极法准确可靠,适用于卷烟纸中钾含量的快速检测。

    Abstract:

    Objective:A method for simple and rapid determination of potassium content in cigarette paper will be built for workshops of cigarette factory.Methods:An ion-selective electrode method was used by comparing with the pretreatment methods for cigarette paper samples and potential response behaviors of potassium ion-selective electrodes in different buffer solutions.Results: The potassium ion selective electrode possessed excellent response performance for K+in lithium acetate buffer solution (0.1 mol/L, pH 7.0) with a linear response range of 1.0×10-5~1.0×10-2mol/L, a slope of 55.79 mV/dec(25 ℃), and a lower limit of detection of 2.14×10-6mol/L. The average relative standard deviations of the K+selective electrode on cigarette paper samples were 0.55% for intra-day test and 2.8% for inter-day test, both less than 5%. The test results of the electrode method were in well agreement with that of ion chromatography, with an average relative deviation of 4.1% (n=10) and recoveries between 95.0% and 101.9%. It was demonstrated effectively through a consecutive test over one week.Conclusion: Among the pretreatment methods for cigarette paper samples, the ultrasonic extraction of potassium ions with 1% diluted acetic acid for 30 min has been found to be fast, simple and environmentally friendly. The ion-selective electrode method is accurate and reliable, which is suitable for the rapid detection of potassium in cigarette paper.

    参考文献
    相似文献
    引证文献
引用本文

陈鹏飞,王思露,喻赛波,等.卷烟纸中钾含量的快速检测[J].食品与机械,2022,(6):96-102.
CHEN Peng-fei, WANG Si-lu, YU Sai-bo, et al. Development of rapid detection technique for potassium content in cigarette paper[J]. Food & Machinery,2022,(6):96-102.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2022-09-02
  • 出版日期:
文章二维码
×
《食品与机械》
友情提示
友情提示 一、 近日有不少作者反应我刊官网无法打开,是因为我刊网站正在升级,旧网站仍在百度搜索排名前列。请认准《食品与机械》唯一官方网址:http://www.ifoodmm.com/spyjx/home 唯一官方邮箱:foodmm@ifoodmm.com; 联系电话:0731-85258200,希望广大读者和作者仔细甄别。