QuEChERS—高效液相色谱法检测柑桔中毒死蜱、吡虫啉和残杀威农残
CSTR:
作者:
作者单位:

(1. 西南大学柑桔研究所,重庆 400712;2. 西南大学食品科学学院,重庆 400715)

作者简介:

孙志高(1964—),男,西南大学副研究员,硕士生导师。E-mail: cpro@cric.cn

通讯作者:

中图分类号:

基金项目:

四川省科技计划项目(编号:2014NZ0062)


Detected chlorpyrifos, imidacloprid, and propoxur residues in citrus by QuEChERS-high performance liquid chromatography method
Author:
Affiliation:

(1. College of Food Science Southwest University, Chongqing 400715, China; 2. Southwest University, Citrus Research Institute, Chongqing 400712, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    将改进的QuEChERS方法与GB/T 24691—2009中农药提取方法进行比较,通过高效液相色谱法检测2种方法对柑桔农残的分离效果。结果显示:改进的QuEChERS方法检测毒死蜱、吡虫啉和残杀威时出峰时间分别约为5.1,3.8,11.5 min;当空白加标水平分别为0.8~80.0,0.5~40.0,0.8~80.0 μg/mL时,检出限分别为0.89,0.55,0.39 μg/mL;当空白加标水平分别为1~20,1~20,5~30 μg/mL时,回收率分别为68%~109%,94%~108%,109%~125%,相对标准偏差分别为2.48%~5.03%,7.79%~10.92%,2.32%~6.77%。采用GB/T 24691—2009提取毒死蜱、吡虫啉和残杀威时,出峰时间与改进的QuEChERS方法基本相同;当与改进的QuEChERS方法采用相同的空白加标水平,检出限分别为0.80,0.78,0.54 μg/mL,回收率分别为107%~195%,25%~87%,53%~93%,相对标准偏差分别为5.61%~7.73%,6.89%~9.42%,5.44%~10.45%。因此,QuEChERS—高效液相色谱法检测毒死蜱、吡虫啉和残杀威农残时优于GB/T 24691—2009方法。

    Abstract:

    QuEChERS is a simple and efficient extraction method, widely used in the pesticide of residue detection. The purpose of this paper was to compare the extraction methods of pesticides between the improved QuEChERS method and the GB/T 24691—2009 (fruit and vegetable detergent). The extraction of pesticide residue from citrus samples were detected by HPLC. The results showed that when the chlorpyrifos, imidacloprid and propoxur were detected by the improved QuEChERS method, the peak time was about 5.1, 3.8, 11.5 min, respectively. When the spiked blank levels were 0.8~80, 0.5~40, 0.8~80 μg/mL, the detection limits were 0.89, 0.55, and 0.39 μg/mL. While the spiked blank levels respectively were in 1~20, 1~20, 5~30 μg/mL, the recovery rate was 68%~109%, 94%~108%, 109%~125% and the relative standard deviation was 2.48%~5.03%, 7.79%~10.92%, 2.32%~6.77% respectively. When the fruit and vegetable detergent extracted from GB/T 24691—2009, the peak time of chlorpyrifos, imidacloprid and propoxur was basically the same as the modified QuEChERS method. Moreover, when the same spiked blank level was applied to the improved QuEChERS method, the detection limits were 0.80, 0.78, and 0.54 μg/mL, respectively, The recoveries were 107%~195%, 25%~87% and 53%~93%, and the relative standard deviations were 5.61%~7.73%, 6.89%~9.42% and 5.44%~10.45%, respectively. Thus, it indicated that the improved QuEChERS-HPLC was better than GB/T 24691—2009 (fruit and vegetable detergent).

    参考文献
    相似文献
    引证文献
引用本文

孙志高,盛冉,郝静梅,等. QuEChERS—高效液相色谱法检测柑桔中毒死蜱、吡虫啉和残杀威农残[J].食品与机械,2017,33(6):68-72.
SUNZhigao, SHENGRan, HAOJingmei, et al. Detected chlorpyrifos, imidacloprid, and propoxur residues in citrus by QuEChERS-high performance liquid chromatography method[J]. Food & Machinery,2017,33(6):68-72.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-03-10
  • 出版日期:
文章二维码
×
《食品与机械》
友情提示
友情提示 一、 近日有不少作者反应我刊官网无法打开,是因为我刊网站正在升级,旧网站仍在百度搜索排名前列。请认准《食品与机械》唯一官方网址:http://www.ifoodmm.com/spyjx/home 唯一官方邮箱:foodmm@ifoodmm.com; 联系电话:0731-85258200,希望广大读者和作者仔细甄别。